{ "entries": [ { "name": "SpyManager_Slot13RngCallee", "addr": "0x008408e0", "convention": "thiscall", "prototype": "int (void* this, int, int) // the ONE callee through which Game::ServerSpyManager vftable 0x00a3073c slot 13 (0x008877b0) reaches the strategic generator. Exactly ONE incoming reference in the image: an unconditional call at 0x00887af2 inside that slot. Real body 0x008408e0..0x00840a59, 370 bytes. Contains three of lane V2's eight draw sites -- Chance 0x00840929, NextInt 0x008409c7, Chance 0x00840a3c -- all loading the generator as [reg+0x16c]. Named for the verified relationship (which slot reaches it, and that it draws), NOT for any semantics: its body was not read. Lane H hooks it with a register-transparent entry counter so that 'the spy path never fired' can be split into 'slot 13 was not entered' and 'slot 13 was entered and gated above this call'", "status": "mapped", "source": "findings/control-flow/tail-probes.md" }, { "name": "TradeManager_Slot13RngCalleeA", "addr": "0x00820ca0", "convention": "thiscall", "prototype": "uint (void* fleet, char) // first of the two callees through which Game::ServerTradeManagerImpl vftable 0x00a31b74 slot 13 (0x0088ef80) reaches the strategic generator. Exactly ONE incoming reference: an unconditional call at 0x0088f036. Real body 0x00820ca0..0x00820e53, 436 bytes, containing lane V2's NextFloat site 0x00820e18. Its own body loops the vector at arg+0xa4/+0xa8 testing per-element flags, and its boolean result is what gates the call to TradeManager_Slot13RngCalleeB one instruction later. THE CALLER'S LOOP IS OVER THE FLEETS VECTOR at GetServer()+0x64/+0x68, not over a trade-route list -- which is why 'the tail draws nothing because we have no trade routes' does not explain this slot", "status": "mapped", "source": "findings/control-flow/tail-probes.md" }, { "name": "TradeManager_Slot13RngCalleeB", "addr": "0x0088b440", "convention": "thiscall", "prototype": "void (void* this, int) // second of the two callees through which Game::ServerTradeManagerImpl slot 13 (0x0088ef80) reaches the strategic generator, called at 0x0088f042 ONLY when TradeManager_Slot13RngCalleeA returned non-zero. Exactly ONE incoming reference. Real body 0x0088b440..0x0088b976, 1323 bytes, containing lane V2's NextInt site 0x0088b613 (`mov ecx,[ecx+0x16c]; add ecx,4`). The two form a two-stage gate: A draws first and decides whether B runs, so a run where A fires and B does not is a MEASUREMENT, not a gap", "status": "mapped", "source": "findings/control-flow/tail-probes.md" } ] }