Nine single parcels (Bristol, Clinton 24178020, East Haddam 24196088, Ellington, Haddam 24082788, New Milford, Somers, Willington 24206510, Winchester) and the four Hebron package parcels now have findings, a verdict, the native 2 ft leaf-off LIDAR hillshade, and report.html. README candidate rows and the Hebron parcel table link the new pages.
61 lines
2.4 KiB
JSON
61 lines
2.4 KiB
JSON
{
|
|
"schemaVersion": "1.0.0",
|
|
"agent": "soil",
|
|
"generatedAt": "2026-10-05T23:30:00.000Z",
|
|
"parcelId": "06-46",
|
|
"sourceBoundarySha256": "26e74cb5d1e1a64f6cf4709405efcdcb21a239bcb3e9c4b457279dcb8782ded6",
|
|
"status": "complete",
|
|
"summary": "29.5 of 52.8 mapped acres rate Class VII and 7.1 acres are 94% hydric. Only 2.3 acres are Class II prime farmland.",
|
|
"flags": [
|
|
{
|
|
"id": "soil:boundary-gap",
|
|
"severity": "high",
|
|
"kind": "boundary",
|
|
"label": "2.78 ac gap: 52.80 mapped vs 50.02 listed; extent unverified",
|
|
"detail": "Subdivision scan 2003, deed, and survey are needed to reconcile acreage and limits.",
|
|
"zones": [],
|
|
"evidence": ["property.json", "property-data.json"]
|
|
},
|
|
{
|
|
"id": "soil:septic-hydric",
|
|
"severity": "high",
|
|
"kind": "septic",
|
|
"label": "7.1 ac extremely stony, 94% hydric (3); septic unverified",
|
|
"detail": "No test pit, perc result, septic design, or approval is on file.",
|
|
"zones": ["3"],
|
|
"evidence": ["wss/hydric.txt", "property.json"]
|
|
},
|
|
{
|
|
"id": "soil:class7-rocky",
|
|
"severity": "medium",
|
|
"kind": "soil",
|
|
"label": "18.0 ac Class VII, 15-45% very rocky (73E)",
|
|
"detail": "Charlton-Chatfield complex is the largest unit; 29.5 ac are Class VII in total.",
|
|
"zones": ["73E", "62C"],
|
|
"evidence": ["wss/capability.txt", "wss/soil-map.txt"]
|
|
},
|
|
{
|
|
"id": "soil:class6-stony",
|
|
"severity": "medium",
|
|
"kind": "soil",
|
|
"label": "21.0 ac Class VI, very stony or very rocky",
|
|
"detail": "Units 73C, 61B, and 51B; severe limitations for cultivation.",
|
|
"zones": ["73C", "61B", "51B"],
|
|
"evidence": ["wss/capability.txt"]
|
|
},
|
|
{
|
|
"id": "soil:prime-limited",
|
|
"severity": "medium",
|
|
"kind": "soil",
|
|
"label": "2.3 ac Class II prime farmland (60B)",
|
|
"detail": "Mapped unit only; not confirmed open, contiguous, or accessible.",
|
|
"zones": ["60B"],
|
|
"evidence": ["wss/capability.txt", "wss/farmland.txt"]
|
|
}
|
|
],
|
|
"metrics": { "wssAoiAcres": 52.8, "classIIAcres": 2.3, "classVIAcres": 21.0, "classVIIAcres": 29.5, "hydricUnitAcres": 7.1, "listedAcres": 50.02 },
|
|
"unresolved": [
|
|
"Passing septic feasibility review and accepted primary/reserve design for the intended building and use.",
|
|
"Field-verified contiguous vegetable/orchard ground, stone burden, drainage, and wetland constraints."
|
|
]
|
|
}
|