Findings JSON, report.html, and report manifests for East Hampton, Goshen, Sharon Lot 3, East Haddam, Torrington, Wolcott, Willington, and Woodstock; native 2 ft leaf-off hillshade cached for each; README candidate table rebuilt from the property folders.
21 lines
2 KiB
JSON
21 lines
2 KiB
JSON
{
|
||
"schemaVersion": "1.0.0",
|
||
"agent": "soil",
|
||
"generatedAt": "2026-10-05T23:30:00Z",
|
||
"parcelId": "022-015",
|
||
"sourceBoundarySha256": "b64660a7caa3d9583d7a364978c1799226a0b941172a21ca1d2949ba4ebc4067",
|
||
"status": "complete",
|
||
"summary": "All 31.7 mapped acres rate Class VI or VII, and 5.4 acres are a 94%-hydric-component unit. No prime farmland; 9.1 acres are statewide importance.",
|
||
"flags": [
|
||
{"id":"soil:septic-hydric","severity":"high","kind":"septic","label":"5.4 ac hydric unit (94%); septic feasibility unverified","detail":"No test pit, perc result, septic design, or approval is on file.","zones":["3"],"evidence":["wss/hydric.txt","property.json"]},
|
||
{"id":"soil:class7-rocky","severity":"medium","kind":"soil","label":"7.8 ac Class VII, 15–45% very rocky (73E)","detail":"Charlton-Chatfield complex is the largest single unit.","zones":["73E"],"evidence":["wss/capability.txt","wss/soil-map.txt"]},
|
||
{"id":"soil:all-class6-7","severity":"medium","kind":"soil","label":"31.7 ac all Class VI or VII; 16.4 ac Class VII","detail":"Every unit is very stony, extremely stony, or very rocky.","zones":["3","52C","73E","75E"],"evidence":["wss/capability.txt"]},
|
||
{"id":"soil:no-prime","severity":"info","kind":"soil","label":"0 ac prime farmland; 9.1 ac statewide importance","detail":"Statewide-importance units are Class VI and very stony.","zones":["46B","51B","61C"],"evidence":["wss/farmland.txt"]},
|
||
{"id":"soil:acreage-gap","severity":"info","kind":"boundary","label":"31.7 ac mapped versus 31.29 ac listed","detail":"Tax-map outline is not a survey; the 0.35 ac gap is unresolved.","zones":[],"evidence":["property.json","boundary.geojson"]}
|
||
],
|
||
"metrics": {"wssAoiAcres":31.7,"classVIAcres":15.3,"classVIIAcres":16.4,"hydricUnitAcres":5.4,"statewideImportanceAcres":9.1,"primeFarmlandAcres":0},
|
||
"unresolved": [
|
||
"Passing septic feasibility review and accepted primary/reserve design for the intended building and use.",
|
||
"Field-verified contiguous vegetable/orchard ground, stone burden, drainage, and clearing feasibility."
|
||
]
|
||
}
|