#!/usr/bin/env bash
|
|
# infra/host/fly-nvidia-majors.sh — installed BY HAND on the host as
|
|
# /usr/local/sbin/fly-nvidia-majors.sh, run by fly-nvidia-majors.service
|
|
# before pve-guests.service on every boot. See infra/host/README.md for the
|
|
# install steps and docs/design/gpu.md section 1 for why it exists.
|
|
#
|
|
# fly-nvidia-majors.sh [--dry-run] CTID [CTID...]
|
|
#
|
|
# What it does, per docs/design/gpu.md section 1:
|
|
# 1. `nvidia-modprobe -u -c 0 -m` so /dev/nvidia-uvm{,-tools} and
|
|
# /dev/nvidia-caps/* actually exist (loading the modules is what
|
|
# allocates their majors in the first place).
|
|
# 2. Reads the three majors it needs out of /proc/devices, live:
|
|
# nvidia -> 195, compile-time static (NV_MAJOR_DEVICE_NUMBER),
|
|
# covers nvidia0 / nvidiactl / nvidia-modeset
|
|
# nvidia-uvm -> DYNAMIC, changes every boot (509 -> 511 on the LLM host on
|
|
# 2026-08-29; 511 on the host on 2026-09-15)
|
|
# nvidia-caps -> DYNAMIC (236 on the host on 2026-09-15)
|
|
# 3. Rewrites the `# BEGIN fly-nvidia` .. `# END fly-nvidia` block in
|
|
# /etc/pve/lxc/<id>.conf for each id given, and writes the file back
|
|
# ONLY if the result differs.
|
|
#
|
|
# Three deliberate properties, each of which is a bug that has actually
|
|
# happened on the operator's hosts:
|
|
#
|
|
# * It REFUSES to write anything if any major came back empty. A truncated
|
|
# or malformed /proc/devices read must not turn into
|
|
# `lxc.cgroup2.devices.allow: c :* rwm` in a production container's conf.
|
|
# * It builds the new file in $TMPDIR (default /tmp) and then `cat >`s it
|
|
# into place. /etc/pve is pmxcfs (a FUSE filesystem backed by the cluster
|
|
# config DB); `mv` across filesystems into it is not reliable, and every
|
|
# write is a cluster transaction, so needless writes are avoided too.
|
|
# * It is idempotent, so it is safe on a timer, from a unit, or by hand
|
|
# while debugging, and a second run reports `unchanged`.
|
|
#
|
|
# Output contract (this is consumed by infra/01-create-ct.sh): exactly one
|
|
# line per CTID on stdout, `<ctid> changed` or `<ctid> unchanged` (or
|
|
# `<ctid> missing` when there is no conf file for it). All logging goes to
|
|
# stderr.
|
|
#
|
|
# This script is HOST-SIDE. It is the one file in this repo that runs
|
|
# outside a container, does not take an env file, and is installed by hand
|
|
# rather than by provision.sh — /etc/pve is not reachable through pct exec,
|
|
# and a boot-ordered host unit is not something a per-container script
|
|
# should be installing behind the operator's back.
|
|
set -euo pipefail
|
|
|
|
BLOCK_BEGIN='# BEGIN fly-nvidia'
|
|
BLOCK_END='# END fly-nvidia'
|
|
DRY_RUN=0
|
|
|
|
# Two test hooks, both defaulting to the only values that matter in
|
|
# production. They exist so the sentinel-block rewrite can be exercised
|
|
# without a GPU and without touching /etc/pve (infra/tests/lint.sh does
|
|
# exactly that), and for `--dry-run` against a copied conf while debugging.
|
|
# Nothing in the repo sets them for a real run.
|
|
: "${PROC_DEVICES:=/proc/devices}"
|
|
: "${LXC_CONF_DIR:=/etc/pve/lxc}"
|
|
|
|
log() { printf 'fly-nvidia-majors: %s\n' "$*" >&2; }
|
|
die() { printf 'fly-nvidia-majors: FATAL: %s\n' "$*" >&2; exit 1; }
|
|
|
|
usage() {
|
|
echo "usage: $0 [--dry-run] CTID [CTID...]" >&2
|
|
exit 2
|
|
}
|
|
|
|
while [ $# -gt 0 ]; do
|
|
case "$1" in
|
|
--dry-run) DRY_RUN=1; shift ;;
|
|
-h|--help) usage ;;
|
|
--) shift; break ;;
|
|
-*) die "unknown option: $1" ;;
|
|
*) break ;;
|
|
esac
|
|
done
|
|
|
|
[ $# -ge 1 ] || usage
|
|
|
|
for id in "$@"; do
|
|
case "$id" in
|
|
''|*[!0-9]*) die "not a container id: '$id'" ;;
|
|
esac
|
|
done
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# 1. Materialise the device nodes. Harmless and idempotent when they already
|
|
# exist; `-u` is uvm, `-c 0` is the caps directory for GPU 0, `-m` is
|
|
# nvidia-modeset. Matches the host's existing nvidia-devnodes.service, which
|
|
# does exactly this and nothing else (which is why the neighbouring GPU container's majors went
|
|
# stale: nothing rewrote them).
|
|
# ---------------------------------------------------------------------------
|
|
if command -v nvidia-modprobe >/dev/null 2>&1; then
|
|
nvidia-modprobe -u -c 0 -m || log "WARNING: nvidia-modprobe -u -c 0 -m exited nonzero; continuing to read /proc/devices anyway"
|
|
else
|
|
log "WARNING: nvidia-modprobe not found; relying on the modules already being loaded"
|
|
fi
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# 2. Read the majors, live. `$2 == name` (not a regex match) so that
|
|
# `nvidia` does not also match `nvidia-uvm`, `nvidia-modeset`,
|
|
# `nvidia-nvswitch` or `nvidia-nvlink`, all of which appear in
|
|
# /proc/devices on this host.
|
|
# ---------------------------------------------------------------------------
|
|
read_major() {
|
|
awk -v n="$1" '$2 == n { print $1; exit }' "$PROC_DEVICES"
|
|
}
|
|
|
|
MAJ_NVIDIA="$(read_major nvidia || true)"
|
|
MAJ_UVM="$(read_major nvidia-uvm || true)"
|
|
MAJ_CAPS="$(read_major nvidia-caps || true)"
|
|
|
|
for pair in "nvidia:${MAJ_NVIDIA}" "nvidia-uvm:${MAJ_UVM}" "nvidia-caps:${MAJ_CAPS}"; do
|
|
name="${pair%%:*}"
|
|
val="${pair#*:}"
|
|
case "$val" in
|
|
''|*[!0-9]*)
|
|
die "refusing to write: major for '$name' read from /proc/devices is '${val}', not a number. Is the driver loaded? Check: grep nvidia $PROC_DEVICES"
|
|
;;
|
|
esac
|
|
done
|
|
|
|
log "majors: nvidia=${MAJ_NVIDIA} nvidia-uvm=${MAJ_UVM} nvidia-caps=${MAJ_CAPS}"
|
|
if [ "$MAJ_NVIDIA" != 195 ]; then
|
|
log "WARNING: nvidia major is ${MAJ_NVIDIA}, not the expected compile-time-static 195 — worth a look, but writing it as read"
|
|
fi
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# 3. The block itself (docs/design/gpu.md section 1).
|
|
#
|
|
# /dev/nvidia-modeset is deliberately NOT bound: the NVENC-only design has
|
|
# no in-container Xorg and no EGL display, and binding it hands the guest
|
|
# modesetting ioctls for nothing. If gpu.md section 3 option (b) or (d) is
|
|
# ever taken, add:
|
|
# lxc.mount.entry: /dev/nvidia-modeset dev/nvidia-modeset none bind,optional,create=file
|
|
#
|
|
# nvidia-caps is bound as a DIRECTORY (create=dir), which is what the neighbouring GPU container does
|
|
# and what is proven to work on this host.
|
|
#
|
|
# `optional` is load-bearing in both directions: without it a missing node
|
|
# blocks container start, so a post-kernel-update driver failure takes the
|
|
# whole stream down instead of degrading to the x264 path — but WITH it a
|
|
# broken bind is silent, and `optional,create=file` materialises an empty
|
|
# REGULAR FILE where a character device should be. That is the exact tell the
|
|
# operator's own GPU-driver notes record, and it is what infra/verify.sh's
|
|
# char-device check exists to catch.
|
|
# ---------------------------------------------------------------------------
|
|
render_block() {
|
|
cat <<EOF
|
|
lxc.cgroup2.devices.allow: c ${MAJ_NVIDIA}:* rwm
|
|
lxc.cgroup2.devices.allow: c ${MAJ_UVM}:* rwm
|
|
lxc.cgroup2.devices.allow: c ${MAJ_CAPS}:* rwm
|
|
lxc.mount.entry: /dev/nvidia0 dev/nvidia0 none bind,optional,create=file
|
|
lxc.mount.entry: /dev/nvidiactl dev/nvidiactl none bind,optional,create=file
|
|
lxc.mount.entry: /dev/nvidia-uvm dev/nvidia-uvm none bind,optional,create=file
|
|
lxc.mount.entry: /dev/nvidia-uvm-tools dev/nvidia-uvm-tools none bind,optional,create=file
|
|
lxc.mount.entry: /dev/nvidia-caps dev/nvidia-caps none bind,optional,create=dir
|
|
EOF
|
|
}
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# 4. Converge one conf file.
|
|
#
|
|
# Ownership is by LINE, not by position, and that is load-bearing. PVE
|
|
# REWRITES /etc/pve/lxc/<id>.conf on every lifecycle operation and does not
|
|
# preserve layout: measured on PVE 9.2.10 (the host, 2026-09-16), one
|
|
# `pct stop` / `pct start` of the dev container re-emitted the conf with every PVE key
|
|
# sorted alphabetically, every COMMENT hoisted to the top of the file, and
|
|
# every raw `lxc.*` key moved to the end. The `# BEGIN fly-nvidia` /
|
|
# `# END fly-nvidia` pair ends up adjacent and EMPTY at the top, with the
|
|
# eight lines it used to bracket sitting at the bottom outside any block.
|
|
#
|
|
# A converge that trusted those comments would then, on the next boot:
|
|
# delete the empty block, append a fresh one, and leave the hoisted-out
|
|
# lines in place as duplicates. Harmless on the day it happens, and a silent
|
|
# breaker the day after a driver change, because those duplicates carry the
|
|
# OLD dynamic majors and nothing ever removes them — which is precisely the
|
|
# failure this unit exists to prevent (it is how the neighbouring GPU container came to allow
|
|
# `c 509:*`).
|
|
#
|
|
# So a line is owned if it is one of the lines we generate, or if it is:
|
|
#
|
|
# * `lxc.mount.entry: /dev/<one of OUR five targets> ...` — so a bind with
|
|
# different options is replaced rather than duplicated. /dev/nvidia-modeset
|
|
# is deliberately NOT in that list: the neighbouring GPU container binds it, we do not, and
|
|
# deleting a device out of a production container's config is not this
|
|
# script's job.
|
|
# * `lxc.cgroup2.devices.allow: c N:* rwm` where N is one of the three
|
|
# majors we are writing, or N is registered to a device whose name starts
|
|
# with `nvidia` (e.g. `234`, nvidia-nvswitch, which nothing here wants),
|
|
# or N is registered to NOTHING and sits in a kernel dynamic char-major
|
|
# range (234-254, 384-511) — the signature of one of our own lines from an
|
|
# earlier driver load, which is what the neighbouring GPU container's `c 509:*` is. A major that
|
|
# resolves to a non-NVIDIA device (`226` for /dev/dri), or a static major
|
|
# whose module simply is not loaded, is NOT ours and is left alone.
|
|
#
|
|
# Anything else is reported as a stray and never touched.
|
|
#
|
|
# "unchanged" therefore means: every desired line appears exactly once
|
|
# somewhere in the file and no owned-but-undesired line appears at all.
|
|
# Comments and position are not compared, because PVE owns them and will
|
|
# move them again on the next start. The sentinels are still written, as the
|
|
# only in-file signpost for a human; after the next `pct start` they will be
|
|
# at the top with nothing between them, and that is expected, not a fault.
|
|
# ---------------------------------------------------------------------------
|
|
|
|
# owned_majors CONF — the majors in CONF's `devices.allow: c N:* rwm` lines
|
|
# that this script considers its own, per the rules above. One per line.
|
|
owned_majors() {
|
|
local conf="$1" maj name
|
|
sed -n 's|^lxc\.cgroup2\.devices\.allow: c \([0-9]\{1,\}\):\* rwm$|\1|p' "$conf" \
|
|
| sort -u \
|
|
| while read -r maj; do
|
|
[ -n "$maj" ] || continue
|
|
case " ${MAJ_NVIDIA} ${MAJ_UVM} ${MAJ_CAPS} " in
|
|
*" ${maj} "*) echo "$maj"; continue ;;
|
|
esac
|
|
name="$(awk -v m="$maj" '$1 == m { print $2; exit }' "$PROC_DEVICES")"
|
|
if [ -n "$name" ]; then
|
|
case "$name" in nvidia*) echo "$maj" ;; esac
|
|
elif { [ "$maj" -ge 234 ] && [ "$maj" -le 254 ]; } \
|
|
|| { [ "$maj" -ge 384 ] && [ "$maj" -le 511 ]; }; then
|
|
# Registered to nothing AND inside a kernel DYNAMIC char-major
|
|
# range (234-254, then the extended 384-511). Only a
|
|
# dynamically allocated major can go stale the way nvidia-uvm
|
|
# and nvidia-caps do, so this is the signature of one of our
|
|
# own lines from an earlier driver load — the neighbouring GPU container's `c 509:*` is
|
|
# exactly this. A STATIC major that simply is not loaded right
|
|
# now (226/drm on a host with no DRM, 116/alsa, ...) is not
|
|
# ours and must survive: deleting an `allow` line for another
|
|
# container's device because its module happened to be
|
|
# unloaded would be a real regression, and infra/tests/lint.sh
|
|
# asserts both halves of this.
|
|
echo "$maj"
|
|
fi
|
|
done
|
|
}
|
|
|
|
converge_conf() {
|
|
local ctid="$1"
|
|
local conf="${LXC_CONF_DIR}/${ctid}.conf"
|
|
|
|
if [ ! -f "$conf" ]; then
|
|
log "no such container conf: $conf (CT ${ctid} not created yet?) — skipping"
|
|
echo "${ctid} missing"
|
|
return 0
|
|
fi
|
|
|
|
local blk new majs
|
|
blk="$(mktemp "${TMPDIR:-/tmp}/fly-nvidia-blk.XXXXXX")"
|
|
new="$(mktemp "${TMPDIR:-/tmp}/fly-nvidia-conf.XXXXXX")"
|
|
|
|
{
|
|
echo "$BLOCK_BEGIN (generated by fly-nvidia-majors.service, do not edit by hand)"
|
|
render_block
|
|
echo "$BLOCK_END"
|
|
} > "$blk"
|
|
|
|
majs="$(owned_majors "$conf" | tr '\n' ' ')"
|
|
|
|
# The awk ownership test, shared by both passes below. Kept in one string
|
|
# so the "is it already right?" check and the rewrite can never disagree.
|
|
local own_prog='
|
|
function is_owned(line, n, i, t, ts, maj) {
|
|
if (line in desired) return 1
|
|
n = split("/dev/nvidia0 /dev/nvidiactl /dev/nvidia-uvm /dev/nvidia-uvm-tools /dev/nvidia-caps", ts, " ")
|
|
for (i = 1; i <= n; i++) {
|
|
t = "lxc.mount.entry: " ts[i] " "
|
|
if (index(line, t) == 1) return 1
|
|
}
|
|
if (match(line, /^lxc\.cgroup2\.devices\.allow: c [0-9]+:\* rwm$/)) {
|
|
maj = line
|
|
sub(/^lxc\.cgroup2\.devices\.allow: c /, "", maj)
|
|
sub(/:\* rwm$/, "", maj)
|
|
if ((" " majs " ") ~ (" " maj " ")) return 1
|
|
}
|
|
return 0
|
|
}
|
|
BEGIN {
|
|
while ((getline line < desiredfile) > 0) if (line != "") desired[line] = 1
|
|
close(desiredfile)
|
|
}
|
|
'
|
|
|
|
# Pass 1: already semantically correct? Then write nothing at all.
|
|
if awk -v majs="$majs" -v desiredfile="$blk" "
|
|
$own_prog
|
|
{ if (is_owned(\$0)) seen[\$0]++ }
|
|
END {
|
|
for (d in desired) if (d !~ /^# (BEGIN|END) /) if (seen[d] != 1) exit 1
|
|
for (s in seen) if (!(s in desired)) exit 1
|
|
exit 0
|
|
}
|
|
" "$conf"; then
|
|
report_strays "$conf" "$majs"
|
|
rm -f "$blk" "$new"
|
|
echo "${ctid} unchanged"
|
|
return 0
|
|
fi
|
|
|
|
# Pass 2: rewrite. Drop every owned line and both sentinels wherever they
|
|
# are, then re-emit the block before the first `[section]` or at EOF —
|
|
# appending blindly would land lxc.* keys inside a snapshot section, where
|
|
# PVE ignores them, silently.
|
|
awk -v majs="$majs" -v desiredfile="$blk" -v b="$BLOCK_BEGIN" -v e="$BLOCK_END" -v blockfile="$blk" "
|
|
$own_prog
|
|
function emit( line) {
|
|
while ((getline line < blockfile) > 0) print line
|
|
close(blockfile)
|
|
}
|
|
index(\$0, b) == 1 { next }
|
|
index(\$0, e) == 1 { next }
|
|
is_owned(\$0) { next }
|
|
/^\[/ && !done { emit(); done = 1 }
|
|
{ print }
|
|
END { if (!done) emit() }
|
|
" "$conf" > "$new"
|
|
|
|
report_strays "$conf" "$majs"
|
|
|
|
if cmp -s "$new" "$conf"; then
|
|
rm -f "$blk" "$new"
|
|
echo "${ctid} unchanged"
|
|
return 0
|
|
fi
|
|
|
|
if [ "$DRY_RUN" -eq 1 ]; then
|
|
log "DRY RUN: would rewrite $conf; diff follows"
|
|
diff -u "$conf" "$new" >&2 || true
|
|
else
|
|
# pmxcfs: write THROUGH the existing inode with `cat >`, never `mv` a
|
|
# /tmp file across the filesystem boundary into /etc/pve.
|
|
cat "$new" > "$conf"
|
|
log "rewrote the fly-nvidia block in $conf"
|
|
fi
|
|
|
|
rm -f "$blk" "$new"
|
|
echo "${ctid} changed"
|
|
}
|
|
|
|
# report_strays CONF OWNED_MAJORS — NVIDIA-shaped device lines this script
|
|
# does NOT own are reported, never silently deleted. The neighbouring GPU container's
|
|
# /dev/nvidia-modeset bind is the live example: it belongs to the LLM work,
|
|
# not to this unit.
|
|
report_strays() {
|
|
local conf="$1" majs="$2" stray
|
|
stray="$(awk -v majs="$majs" '
|
|
function ours(line, n, i, t, ts, maj) {
|
|
n = split("/dev/nvidia0 /dev/nvidiactl /dev/nvidia-uvm /dev/nvidia-uvm-tools /dev/nvidia-caps", ts, " ")
|
|
for (i = 1; i <= n; i++) {
|
|
t = "lxc.mount.entry: " ts[i] " "
|
|
if (index(line, t) == 1) return 1
|
|
}
|
|
if (match(line, /^lxc\.cgroup2\.devices\.allow: c [0-9]+:\* rwm$/)) {
|
|
maj = line
|
|
sub(/^lxc\.cgroup2\.devices\.allow: c /, "", maj)
|
|
sub(/:\* rwm$/, "", maj)
|
|
if ((" " majs " ") ~ (" " maj " ")) return 1
|
|
}
|
|
return 0
|
|
}
|
|
/^lxc\.mount\.entry:[[:space:]]*\/dev\/nvidia/ { if (!ours($0)) print; next }
|
|
/^lxc\.cgroup2\.devices\.allow:/ { if (!ours($0)) print; next }
|
|
' "$conf" || true)"
|
|
if [ -n "$stray" ]; then
|
|
log "NOTE: $conf has NVIDIA/device lines this script does not own; they are left alone. Review and delete by hand if stale:"
|
|
printf '%s\n' "$stray" | sed 's/^/ /' >&2
|
|
fi
|
|
}
|
|
|
|
for id in "$@"; do
|
|
converge_conf "$id"
|
|
done
|
|
|
|
log "done ($#: $*)"
|