fly-runtime session now stops a running shadow and its guard (fly-shadow-run stop,
no flysim restart) once flysim is healthy on the session runtime, so the guard
cannot judge the session against the legacy baseline during the probation. The
runbook cutover drops the restart in step 5.
fly-shadow-run start refuses, starting nothing, unless flyshadow's cpuset drop-in
exists and its AllowedCPUs is non-empty and disjoint from flysim.service's.
Tests in infra/tests/lint.sh cover both.
Review round 3, G1-a: the guard stops only when flyshadow's ActiveState is inactive or failed
(systemctl show), not while it is activating/auto-restart. check also requires the guard timer
active and baseline.json. allows_cutover refuses an updatedAt more than 60 s ahead of the clock.
Lint drives the guard and check with a fake systemctl; a real systemd 257 user manager run is
kept in the review notes.
A real recording (a flysim whose box load stepped 1.0 -> 0.66 inside the
10-minute window) widened the old mean/sd margin to 0.25 and hid a
genuine shadow-induced drop to 0.44-0.60. The baseline RTF is now the
median of the window, its spread 1.4826 x the median absolute deviation,
and the lag rate is taken over the most recent half. The recording now
trips at check 7; over 800 synthetic 3-hour runs shaped on the release
CT (flat 0.66, 0.77-0.99 and 0.6-1.0 noisy, per second and per sample)
there is no false trip, and all 400 degradations (to 0.55-0.75, and
0.66 -> 0.58) trip.
fly-shadow-run start measures a 10-minute baseline before the shadow
exists (sixty 10-s realtime-factor means: mean, spread; the lag growth
rate). The guard trips only on a sustained degradation against it: 3
checks in a row where the last 5 samples of the same process fall below
the baseline realtime factor or grow lag faster than the baseline rate,
by more than max(0.05, 4 x spread / sqrt 5). It stops itself when
flyshadow.service is not running; check refuses after a guard trip or
with the shadow down. lint drives the rule over RTF traces shaped on the
release CT (a flat 0.66, 0.77-0.99 noisy, real time with hiccups) which
must not trip, and degradations which must. Section 18 and the runbook
follow.
fly-shadow-run start records the live fly's baseline (fly_realtime_factor
over 10 s, fly_lag_seconds, uptime), waits for the shadow's heartbeat and
starts flyshadow-guard.timer. fly-shadow-run guard (every 60 s, root)
stops the shadow and the guard, removes the trace drop-in and restarts
flysim without the trace when fly_lag_seconds grew 1 s in the same
process or the mean realtime factor fell below min(0.97, baseline-0.03);
a paused fly is not judged, a restarted one rebaselines. check passes
--current /opt/fly/current --binary flysim-session. lint drives the
guard's rule on six cases. Runbook rewritten: the trace cannot outlive
the shadow (heartbeat, 8 GiB directory cap), not the old claim.
Report-only unit, off by default, not bound to flysim, SCHED_IDLE on the
page and encoder CPUs, stays stopped after a divergence (exit 3).
fly-shadow-run start|stop|status|check installs the flysim trace drop-in,
restarts flysim once and reads the verdict. Deploy, build and packaging
ship fly-shadow and fly-session; lint holds the unit to its rules; the
runbook has a Shadow run section.