Verified on systemd 257: with the default RestartMode=normal the unit passes through failed
before every auto-restart, so OnFailure= ran on the first crash. The session drop-in now sets
RestartMode=direct. session, legacy, fallback and the trap rollback share one flock; a switch
holds it only until its restart is queued (restart --no-block, health checked against the new
invocation), and the rollback skips restoring an older drop-in once a fallback has completed.
lint.sh covers the drop-in key, the interleaving and the shared lock; runbook corrected.
The fallback used to live only inside one 'fly-runtime session' invocation. The session
drop-in now carries OnFailure=fly-runtime-fallback.service and a 3-starts-in-10-minutes
start limit, so a session binary that will not stay up puts flysim.service back on legacy
after a reboot, a watchdog or loop-recover restart or a deploy. 'fly-runtime fallback'
removes the drop-in, daemon-reloads, restarts on legacy, writes /run/fly/runtime-fellback.json
and a journal line; it is locked, idempotent and keeps the drop-in if legacy cannot start.
fly-runtime traps INT/TERM/HUP and any failure during a switch and rolls back to the
previous state. Session drop-in and flysim-session.service set MALLOC_ARENA_MAX=2.
05-deploy keeps the chosen runtime (operator decision: session stays, trust gates),
refreshes the drop-in in place, and says so; the runbook documents all of it.
lint.sh drives the fallback, the interrupts and the deploy policy against a fake systemctl.
fly-runtime session|legacy|status switches which binary flysim.service runs
with one drop-in (flysim.service.d/10-runtime.conf), so fly.target, flyedge's
Requires=, the watchdog, fly-loop-recover and its sudoers line,
fly-loop-reset, fly-reset-to-milestone and the unstick rule keep naming
flysim.service, and the choice survives reboots and deploys. It refuses a
release without flysim-session or with a different compatibility string,
waits for /healthz and an advancing frame, and falls back to legacy by
itself when the session runtime does not come up.
flysim-session.service: the standalone unit (flysim's limits, cpuset and
environment, Conflicts=flysim.service, no [Install]). build-flysim.sh and
package-release.sh ship flysim-session and fly-session; 05-deploy.sh
installs fly-runtime, writes the standalone unit's cpuset drop-in and
refuses a release without flysim-session while the drop-in is present;
tmpfiles creates /run/fly/session. lint.sh checks all of it and drives
fly-runtime against stubs. Runbook: Switch the runtime.
Restart flysim, then reset to the current rung's milestone, then to the
archive below the best rung (never lower), one step per confirmed trap
that outlives the previous one. Two resets a day, three-hour restarts
once they are spent; the ladder starts over at a new best rung or after
six quiet hours. State and history live in the unit's StateDirectory so
a reboot does not forget where the ladder stood.
A router model list confirms each step; a 'not stuck' answer delays it
at most three probes and no answer leaves the watchdog to decide alone.
Each step is announced 60 s ahead in /run/fly/wd/recovery-notice.json
for the stage's recovery splash.
fly-loop-reset is the one new root surface (a sudoers line); 05-deploy
now converges config/fly-sudoers so a release can add it.
Review round 1. flysim reads FLY_FEED_VIA case-insensitively, so check 2 must
too: with Bus in fly.env it read flysim's zeroed counters and would have
escalated to restarting flystage and flycast every pass. It now lowercases.
05-deploy.sh runs the value through feed_via_normalize (lib/common.sh) and
dies on anything but direct|bus, writing the lowercased word, so a typo is a
deploy refusal instead of a flysim boot loop.
lint's fly.target check read only the first physical Wants=/Requires= line;
target_pulls joins backslash continuations and drops comments, with a
fixture that names a unit only on a continuation line. The cpuset loop writes
a flyedge drop-in on the page CPUs, and lint holds it.
Row 58's pad was GO OBJECTIVE into the Pewter Gym and GO OUT straight
back out for 25 minutes, diluted by eight other names, every macro done:
ten distinct names, so the four-name sequence rule could not fire, no
macro near 95%, nothing refused or blocked, and the exploration count
flat. What the window did not have was a reward event.
The stream carries the reward events beside the macros, and one more
rule reads them behind the same no-new-ground gate: WD_LOOP_BUSY_MIN
(100) decisions and no reward in the window, on two probes running, is
'unrewarded'. fly_loop_rewards is exported and loop.json carries
window.rewards. Run against the live row-58 log it flags (211 decisions,
0 rewards, 10 names) where the rules before it did not. Still never
acts: the fixture's two new cases restart nothing.
flyedge.service runs /opt/fly/current/fly-edge After= and Requires=
flysim.service, with its metrics on loopback :9102 and a
ConditionPathExists so a release without the binary leaves it inactive. It is
in no target and 07-enable.sh does not enable it; the header has the switch
and the way back.
build-flysim.sh also builds fly-edge beside the flysim binary and
package-release.sh ships it when present. 05-deploy.sh writes
FLY_FEED_VIA (default direct) into fly.env, flysim.service names
FLY_BUS_DIR=/run/fly/bus and tmpfiles creates it. Watchdog check 2 reads the
feed counters from whoever serves the feed: flyedge when fly.env says bus.
lint.sh holds all of that, and drives check 2's choice against a fixture.
Row 57's pad was one button refused every hold for two hours: one start
and one name in ten brain minutes, so neither the sequence rule nor the
dominance rule could fire, and the coordinator's own watcher saw it
first. Check 10 now reads every macro outcome in the window. The fly's
decisions are its starts and its refusals; `stalled` flags 90% of 20+
decisions ending refused, blocked or timed out, and `zero-progress`
flags decisions with no `done` among them on two probes in a row. Both
sit behind the same no-new-ground gate as the old rules.
fly_loop_refused, fly_loop_blocked and fly_loop_done are exported, and
loop.json carries window.decisions and window.outcomes. It still never
acts: the lint fixture asserts no unit is restarted across six cases,
two of them new (the row-57 log, and a zero-progress log).