infra: RestartMode=direct so OnFailure= fires only at the start limit; one lock for fly-runtime rollback and fallback

Verified on systemd 257: with the default RestartMode=normal the unit passes through failed
before every auto-restart, so OnFailure= ran on the first crash. The session drop-in now sets
RestartMode=direct. session, legacy, fallback and the trap rollback share one flock; a switch
holds it only until its restart is queued (restart --no-block, health checked against the new
invocation), and the rollback skips restoring an older drop-in once a fallback has completed.
lint.sh covers the drop-in key, the interleaving and the shared lock; runbook corrected.
This commit is contained in:
acamilo 2026-09-30 01:36:23 +00:00
parent 405cf11498
commit 6c7c58b35a
5 changed files with 112 additions and 19 deletions

View file

@ -397,7 +397,7 @@ The 'current' symlink has NOT been moved; the running release is untouched."
# the shadow for the new flysim-session binary; the trust gates before the release (the
# parity and service tests, the compat check just below) are what vouch for it. A bad
# release is caught afterwards by the persistent fallback: while the drop-in exists,
# flysim.service carries OnFailure=fly-runtime-fallback.service with a 3-starts-in-10-minutes
# flysim.service carries OnFailure=fly-runtime-fallback.service and RestartMode=direct with a 3-starts-in-10-minutes
# limit, so a session binary that will not stay up puts the fly back on legacy by itself
# (`fly-runtime fallback`, /run/fly/runtime-fellback.json), whoever restarted it.
if ct_exec "$CTID" -- test -f /etc/systemd/system/flysim.service.d/10-runtime.conf; then

View file

@ -41,8 +41,13 @@
# OnFailure=fly-runtime-fallback.service
# StartLimitIntervalSec=600
# StartLimitBurst=3
# [Service]
# RestartMode=direct
#
# so while the session runtime is selected, three starts of flysim.service inside ten minutes
# RestartMode=direct is essential (systemd >= 254; verified on 257): with the default
# RestartMode=normal the unit passes through `failed` before every Restart=always restart and
# OnFailure= fires on the FIRST crash, watchdog kill or start timeout. With `direct` the unit
# goes from one start straight to the next and only the start limit puts it in `failed`. So while the session runtime is selected, three starts of flysim.service inside ten minutes
# (crashes, watchdog kills, a start that never becomes ready, the restarts fly-watchdog and
# fly-loop-recover make for a stream that does not come up) end in the failed state, and systemd
# runs fly-runtime-fallback.service, i.e. `fly-runtime fallback`: write ${FELLBACK_FILE}, remove
@ -68,6 +73,7 @@ set -euo pipefail
: "${FLY_RUNTIME_LOG:=/var/lib/fly/runtime.log}"
: "${FLY_RUNTIME_FELLBACK:=/run/fly/runtime-fellback.json}"
: "${FLY_RUNTIME_LOCK:=/run/fly/runtime.lock}"
: "${FLY_RUNTIME_LOCK_WAIT:=150}"
DROPIN_DIR="${FLY_SYSTEMD_DIR}/${FLY_SERVICE}.d"
DROPIN="${DROPIN_DIR}/10-runtime.conf"
RUNTIME_LOG="$FLY_RUNTIME_LOG"
@ -123,12 +129,15 @@ write_dropin() {
cat >"$tmp" <<EOF
# Written by fly-runtime session (SERVE-01): flysim.service runs the session runtime.
# \`fly-runtime legacy\` removes this file, and so does fly-runtime-fallback.service (OnFailure=,
# after three starts in ten minutes). Keep [Service] in step with units/flysim-session.service.
# after three starts in ten minutes). RestartMode=direct is what makes OnFailure= wait for the start
# limit: systemd >= 254 otherwise passes through the failed state (and OnFailure=) before EVERY auto-restart.
# Keep [Service] in step with units/flysim-session.service.
[Unit]
OnFailure=${FALLBACK_UNIT}
StartLimitIntervalSec=600
StartLimitBurst=3
[Service]
RestartMode=direct
ExecStart=
ExecStart=${SESSION_BIN}
Environment=FLY_SESSION_DIR=${SESSION_DIR}
@ -143,6 +152,11 @@ healthy() {
local deadline=$(( $(date +%s) + FLY_RUNTIME_HEALTH_TIMEOUT ))
local first=""
while [ "$(date +%s)" -lt "$deadline" ]; do
if [ -n "$old_invocation" ] \
&& [ "$(systemctl show -p InvocationID --value "$FLY_SERVICE" 2>/dev/null | head -n1 || true)" = "$old_invocation" ]; then
sleep 1
continue
fi
if curl -fsS -o /dev/null "${FLY_CONTROL_URL}/healthz" 2>/dev/null; then
local frame
frame="$(curl -fsS "${FLY_CONTROL_URL}/status" 2>/dev/null \
@ -161,13 +175,38 @@ healthy() {
return 1
}
# One lock (${FLY_RUNTIME_LOCK}) serialises every change of the drop-in: `fallback`, `session`,
# `legacy` and the rollback in on_exit. A switch holds it from before it reads the current state
# until its restart has been queued (`restart --no-block`), and lets go before the health wait, so
# an OnFailure= fallback is never held up by a start that does not become ready. Re-entrant per
# process. Waits FLY_RUNTIME_LOCK_WAIT (150 s).
locked=0
take_lock() {
if [ "$locked" -eq 1 ]; then return 0; fi
mkdir -p "$(dirname "$FLY_RUNTIME_LOCK")" 2>/dev/null || true
exec 9>>"$FLY_RUNTIME_LOCK"
if flock -w "$FLY_RUNTIME_LOCK_WAIT" 9; then locked=1; return 0; fi
log "could not take ${FLY_RUNTIME_LOCK} within ${FLY_RUNTIME_LOCK_WAIT} s"
return 1
}
drop_lock() {
exec 9>&-
locked=0
}
restarted=0
old_invocation=""
restart_and_check() {
systemctl daemon-reload
systemctl reset-failed "$FLY_SERVICE" 2>/dev/null || true
log "restarting ${FLY_SERVICE} on the $(current) runtime"
restarted=1
systemctl restart "$FLY_SERVICE"
# --no-block: a blocking restart of a unit that never becomes READY holds this process (and
# the lock) for minutes, starving the OnFailure= fallback. `healthy` therefore has to prove
# that it is talking to the NEW invocation, not the old process that is still shutting down.
old_invocation="$(systemctl show -p InvocationID --value "$FLY_SERVICE" 2>/dev/null | head -n1 || true)"
systemctl restart --no-block "$FLY_SERVICE" || { drop_lock; return 1; }
drop_lock
healthy
}
@ -179,9 +218,7 @@ restart_and_check() {
# watchdog) judges health, and a oneshot unit must not sit in a 90 s notify start.
do_fallback() {
local reason="$1" result nrestarts saved
mkdir -p "$(dirname "$FLY_RUNTIME_LOCK")" 2>/dev/null || true
exec 9>>"$FLY_RUNTIME_LOCK"
flock -w 60 9 || log "could not take ${FLY_RUNTIME_LOCK} within 60 s; continuing"
take_lock || log "continuing without the lock"
if [ ! -f "$DROPIN" ]; then
log "fallback: the legacy runtime is already selected; nothing to do"
return 0
@ -221,7 +258,10 @@ do_fallback() {
# An interrupted or failed switch puts the previous state back. `switching` is 1 from just
# before the drop-in is touched until the switch has finished; `prev_dropin` is a copy of the
# drop-in that was there before (empty: none, i.e. legacy).
# drop-in that was there before (empty: none, i.e. legacy). The rollback runs under the lock and
# does nothing when a fallback has completed since the switch began (FELLBACK_FILE exists: the
# switch deleted it under the lock, only a finished fallback writes it): restoring the older
# drop-in then would strand the stream on the session runtime after it was taken off.
switching=0
switch_target=""
prev_dropin=""
@ -231,7 +271,11 @@ on_exit() {
trap - EXIT INT TERM HUP
if [ "$switching" -eq 1 ]; then
switching=0
if [ "$switch_target" = session ]; then
take_lock || true
if [ "$switch_target" = session ] && [ -f "$FELLBACK_FILE" ]; then
record "legacy (switch to session interrupted or failed (exit ${rc}); a fallback completed meanwhile, not restoring the older drop-in)"
restarted=0
elif [ "$switch_target" = session ]; then
if [ -n "$prev_dropin" ] && [ -f "$prev_dropin" ]; then
mkdir -p "$DROPIN_DIR" && cp -f "$prev_dropin" "$DROPIN"
else
@ -299,6 +343,7 @@ if [ "$command" = session ]; then
flysim: ${legacy_compat}
flysim-session: ${session_compat}"
fi
take_lock || die "another fly-runtime holds ${FLY_RUNTIME_LOCK}; not switching"
before="$(current)"
if [ -f "$DROPIN" ]; then
prev_dropin="$(mktemp "${DROPIN}.prev.XXXXXX")"
@ -343,6 +388,7 @@ if [ "$command" = session ]; then
fi
# legacy
take_lock || die "another fly-runtime holds ${FLY_RUNTIME_LOCK}; not switching"
before="$(current)"
switch_target=legacy
switching=1

View file

@ -470,9 +470,13 @@ pct exec $CTID -- /opt/fly/bin/fly-runtime legacy # the one-command rollback
switches back to legacy by itself and exits 1 (`--no-fallback` leaves it to the operator).
Every switch is logged (`journalctl -t fly-runtime`, `/var/lib/fly/runtime.log`).
- **The fallback outlives the switch (C1).** While the session runtime is selected, the drop-in
also sets `OnFailure=fly-runtime-fallback.service`, `StartLimitBurst=3` and
`StartLimitIntervalSec=600`, and `MALLOC_ARENA_MAX=2` (glibc arena fragmentation was the whole
of the 5-8 MB/h RSS growth). Three starts of `flysim.service` within ten minutes, from any
also sets `OnFailure=fly-runtime-fallback.service`, `StartLimitBurst=3`,
`StartLimitIntervalSec=600` and `RestartMode=direct`, and `MALLOC_ARENA_MAX=2` (glibc arena
fragmentation was the whole of the 5-8 MB/h RSS growth). `RestartMode=direct` is what makes the
limit real: since systemd 254 the default (`normal`) sends the unit through the `failed` state
before every `Restart=always` restart, so `OnFailure=` would fire on the first crash, watchdog
kill or start timeout (seen on systemd 257, the container's). With `direct` the unit goes from
one start to the next and only hitting the start limit fails it. Three starts of `flysim.service` within ten minutes, from any
cause and any caller (a reboot, the watchdog or `fly-loop-recover` restarting it, a deploy, a
binary that crashes, hangs before READY or is killed by `WatchdogSec`) make systemd run
`fly-runtime fallback`: it writes `/run/fly/runtime-fellback.json` (time, reason, unit result),
@ -480,13 +484,18 @@ pct exec $CTID -- /opt/fly/bin/fly-runtime legacy # the one-command rollback
a `fly-runtime` journal line. It is idempotent, and it does nothing if the release has no
executable `flysim`. Look with `fly-runtime status` (it prints the reason) or
`cat /run/fly/runtime-fellback.json`; the container is then on legacy until an operator runs
`fly-runtime session` again, which clears the reason file. Three legitimate restarts in ten
`fly-runtime session` again, which clears the reason file. Restarts you make yourself count
too, and once the limit is reached systemd refuses the next start and runs the fallback. Three legitimate restarts in ten
minutes count the same as three crashes: after that many, prefer `fly-runtime legacy`, do the
work, then switch back.
- **Interrupted switches roll back.** `fly-runtime` traps INT, TERM and HUP (an ssh that drops
mid-switch): an unfinished `session` removes the drop-in again (or restores the one that was
there) and restarts `flysim.service` on that state, so a drop-in that never passed its health
check is never left behind.
check is never left behind. `session`, `legacy`, `fallback` and that rollback all take one lock
(`/run/fly/runtime.lock`); a switch holds it while it changes the drop-in and queues the restart
(`systemctl restart --no-block`, so a unit that never becomes READY cannot hold it) and releases
it for the health wait. The rollback does nothing when a fallback finished after the switch began (the
reason file exists), so it can never put back an older drop-in over a fallback.
- **What stays the same.** Everything that names `flysim.service` keeps working unchanged:
`fly.target`, `flyedge.service`'s `Requires=`, the watchdog, `fly-loop-recover`'s restart and
its sudoers line, `fly-loop-reset`, `fly-reset-to-milestone` (run with the service stopped, on

View file

@ -653,7 +653,7 @@ if fly_runtime && [ -f "$rt_dropin" ] \
&& grep -qx "ExecStart=$rt_dir/release/flysim-session" "$rt_dropin" \
&& grep -qx 'ExecStart=' "$rt_dropin" \
&& grep -qx 'Environment=FLY_SESSION_DIR=/run/fly/session' "$rt_dropin" \
&& grep -qx 'restart flysim.service' "$rt_dir/systemctl.log" \
&& grep -qx 'restart --no-block flysim.service' "$rt_dir/systemctl.log" \
&& [ "$(env RT_DIR="$rt_dir" PATH="$rt_dir/bin:$PATH" FLY_SYSTEMD_DIR="$rt_dir/systemd" bash "$INFRA_DIR/bin/fly-runtime" status 2>/dev/null | head -n1)" = session ]; then
pass "fly-runtime session: the drop-in names flysim-session and /run/fly/session, flysim.service restarted, healthy"
else
@ -685,12 +685,13 @@ fly_runtime || fail "fly-runtime session (healthy) failed before the fallback te
if grep -qx 'OnFailure=fly-runtime-fallback.service' "$rt_dropin" \
&& grep -qx 'StartLimitBurst=3' "$rt_dropin" \
&& grep -qx 'StartLimitIntervalSec=600' "$rt_dropin" \
&& grep -qx 'RestartMode=direct' "$rt_dropin" \
&& grep -qx 'Environment=MALLOC_ARENA_MAX=2' "$rt_dropin" \
&& [ -f "$FALLBACK_UNIT" ] \
&& grep -qE '^ExecStart=/opt/fly/bin/fly-runtime fallback$' "$FALLBACK_UNIT" \
&& grep -qx 'Type=oneshot' "$FALLBACK_UNIT" \
&& ! grep -q '^\[Install\]' "$FALLBACK_UNIT"; then
pass "session drop-in: OnFailure= fallback unit, 3 starts in 600 s, MALLOC_ARENA_MAX=2; the unit runs 'fly-runtime fallback'"
pass "session drop-in: OnFailure= fallback unit, 3 starts in 600 s, RestartMode=direct (else OnFailure= fires on every crash), MALLOC_ARENA_MAX=2; the unit runs 'fly-runtime fallback'"
else
fail "session drop-in/fallback unit wrong ($(tr '\n' ' ' < "$rt_dropin"))"
fi
@ -778,7 +779,7 @@ fi
# Signals: an interrupted switch rolls back to the previous state.
rt_interrupt() { # $1 = signal: run `session` on an unhealthy runtime, signal it mid-wait, print its status
local sig="$1" pid rc=0 n=0 base
base="$(rt_ncalls '^restart flysim.service')"
base="$(rt_ncalls '^restart --no-block flysim.service')"
env RT_DIR="$rt_dir" PATH="$rt_dir/bin:$PATH" FLY_RELEASE_DIR="$rt_dir/release" \
FLY_ENV_FILE="$rt_dir/fly.env" FLY_SYSTEMD_DIR="$rt_dir/systemd" \
FLY_RUNTIME_LOG="$rt_dir/runtime.log" FLY_RUNTIME_HEALTH_TIMEOUT=60 RT_HEALTHY=0 \
@ -787,9 +788,10 @@ rt_interrupt() { # $1 = signal: run `session` on an unhealthy runtime, signal i
signal.signal(signal.SIGINT, signal.SIG_DFL) # a background job of a non-interactive shell starts with INT ignored
os.execvp(sys.argv[1], sys.argv[1:])' bash "$INFRA_DIR/bin/fly-runtime" session >/dev/null 2>&1 &
pid=$!
while [ "$(rt_ncalls '^restart flysim.service')" -le "$base" ] && [ "$n" -lt 100 ]; do
while [ "$(rt_ncalls '^restart --no-block flysim.service')" -le "$base" ] && [ "$n" -lt 100 ]; do
n=$((n + 1)); sleep 0.1
done
if [ -n "${2:-}" ]; then "$2" >/dev/null 2>&1 || true; fi
kill "-$sig" "$pid" 2>/dev/null || true
wait "$pid" || rc=$?
echo "$rc"
@ -817,6 +819,41 @@ if [ "$got_rc" = 143 ] && cmp -s "$rt_dropin" "$rt_dir/dropin.before" \
else
fail "an interrupted re-run of session must restore the earlier drop-in (rc=$got_rc)"
fi
# M2, deterministic interleaving: a re-run of `session` over an older drop-in is waiting for
# health, an OnFailure= fallback completes, THEN the switch is interrupted. The rollback must
# not put the older drop-in back (it has no OnFailure=, and the stream would be stranded on the
# session runtime).
# shellcheck disable=SC2317 # called through rt_interrupt
rt_fallback_now() {
env RT_DIR="$rt_dir" PATH="$rt_dir/bin:$PATH" FLY_RELEASE_DIR="$rt_dir/release" \
FLY_SYSTEMD_DIR="$rt_dir/systemd" FLY_RUNTIME_LOG="$rt_dir/runtime.log" \
FLY_RUNTIME_FELLBACK="$rt_fellback" FLY_RUNTIME_LOCK="$rt_dir/run/runtime.lock" \
bash "$INFRA_DIR/bin/fly-runtime" fallback "lint interleaving"
}
mkdir -p "$(dirname "$rt_dropin")"
printf '# older-session-marker\n[Service]\nExecStart=\nExecStart=/previous\n' > "$rt_dropin"
got_rc="$(rt_interrupt TERM rt_fallback_now)"
if [ "$got_rc" = 143 ] && [ ! -f "$rt_dropin" ] && [ -f "$rt_fellback" ] \
&& grep -q 'a fallback completed meanwhile' "$rt_dir/runtime.log"; then
pass "rollback after a completed fallback leaves legacy selected (does not restore the older drop-in)"
else
fail "rollback must not restore an older drop-in after a completed fallback (rc=$got_rc, drop-in present=$([ -f "$rt_dropin" ] && echo yes || echo no))"
fi
# ... and the two share ONE lock: a held lock stops `session` from touching anything.
rm -f "$rt_dropin" "$rt_fellback"
(
exec 8>>"$rt_dir/run/runtime.lock"
flock 8
RT_ARGS=(session)
if ! fly_runtime FLY_RUNTIME_LOCK_WAIT=1 && [ ! -f "$rt_dropin" ]; then
touch "$rt_dir/lock-respected"
fi
)
if [ -f "$rt_dir/lock-respected" ]; then
pass "fly-runtime session waits on the same lock as fallback and does not switch without it"
else
fail "fly-runtime session must take the shared ${FLY_RUNTIME_LOCK:-runtime.lock} lock"
fi
rm -f "$rt_dropin"
mv "$rt_dir/release/flysim-session" "$rt_dir/flysim-session.away"
if ! fly_runtime && [ ! -f "$rt_dropin" ]; then

View file

@ -3,7 +3,8 @@
# The persistent fallback from the session runtime to the legacy loop (SERVE-01 review, C1).
# It is never enabled and in no target: the drop-in that `fly-runtime session` writes on
# flysim.service (10-runtime.conf) carries `OnFailure=fly-runtime-fallback.service` together with
# StartLimitIntervalSec=600 and StartLimitBurst=3, so three starts of flysim.service on the
# StartLimitIntervalSec=600, StartLimitBurst=3 and RestartMode=direct (without it OnFailure= fires on
# every crash, not at the start limit), so three starts of flysim.service on the
# session binary inside ten minutes -- from any cause, and from any caller: a reboot, the
# watchdog, fly-loop-recover, a deploy -- run this unit once. `fly-runtime fallback` removes the
# drop-in (which removes this OnFailure= too), daemon-reloads, restarts flysim.service on the